GERSTEL Olfactory Detector Port ODP
2
The ODP allows the sensing of compounds by a human
nose as they elute from a gas chromatograph. The
effluent is split as it leaves the column so that
it arrives simultaneously at the nose and at a detector(atmospheric
or MSD). This allows additional information on compounds
that are responsible for specific odors.
The ODP 2 is compatible with most GC’s but
when coupled to an Agilent 6890 GC has the following
features:

- Heated Transfer Line is controlled by Agilent
6890 Heated zone eg Auxillary or Detector and requires
no external heater controller
- All fittings for succesfull installation in
6890 are supplied
- Flexible Transfer line can be adjusted to comfortable
position to allow operator to concentrate on olfactory
sensing. Uses switchable integrated humdifier
- Compatible with ODP recorder Software for integration
into GC or GCMSD Chemstation for single system
operation.
Parallel Detection

Is supplied with the ODP to allow simultaneous
operation of the ODP 2 with all commercially available
GC detectors including Mass Spectrometers. A maximum
of two additional detectors can be utilised.
ODP Calc Software
ODP Calc Software is supplied with the Parallel
Detection kit to simplify calculation of suitable
capillary lengths for split ratios between detectors.
Can be set for varying capillary ID’s, Column
flows, headpressures and column oven temperatures.
ODP Recorder consists of:
ODP Recorder Software
The GERSTEL ODP Recorder Software is completely
integrated into the Agilent GC or MSD Chemstation.
It permits identification of components by superimposing
the Olfactogram with the GC or MS Chromatogram.

GERSTEL Olfactory Pad (OP)
The GERSTEL Olfactory Pad allows manual input of
signals in 4 levels of intensity depending on odour
detection. The signals are saved in the format of
the chromatogram together with the GC chromatogram.
The OP is connected via a USB port. No AD Transformer
Card or Analogue Input Card is necessary for the
GC.

Voice Recording
When the OP is pressed, spoken comments can also
be input to correlate with the Olfactogram. These
spoken comments can then be converted by the PC into
text using Voice Recognition Software. These comments
can then appear automatically as a description of
the peaks in the Olfactogram. These comments with
Olfactogram are then superimposed with the GC or
MS Total Ion Chromatogram for identification.
In Australia and New Zealand the ODP 2 is supplied
complete with ODP2, Parallel Detection, ODP Recorder
and suitable fittings for Agilent 6890 installation.
|