GRAPHPACK 2M connection technology
For the rapid and economical connection of capillary
columns to GC systems.
The components of the GRAPHPACK 2M connection technology
are the GRAPHPACK 2M ferrule, the GRAPHPACK 2M adapter
and the GRAPHPACK nut.
GRAPHPACK 2M adapters with Swagelok thread, female
For the conversion of GC systems with Swagelok
fittings to fittings using GRAPHPACK 2M technology.
If a 'male' connection is provided in the detector
or injector inlet - this means that beforehand
a packed column could have been connected directly
- you must order a GRAPHPACK 2M adapter in the
'female' version.
GRAPHPACK 2M adapters with Swagelok thread,
male
For the conversion of GC systems with Swagelok
fittings to fittings using GRAPHPACK 2M technology.
If a ’female’ connection is provided
in the detector or injector inlet – this
means that beforehand a packed column could have
been connected directly – you must order
a GRAPHPACK 2M adapter in the ’male’ version.
GRAPHPACK 2M detector adapters
For the low-priced conversion of detector connections
of various GC manufacturers to GRAPHPACK 2M
connection technology.
The special benefits Connections compatible
with the GERSTEL injection systems CIS and
SIS.
Economical as only one sealing technology is
used for all detectors
GRAPHPACK 2M injector adapters
For the low-priced conversion of injector
connections of various GC manufacturers to
GRAPHPACK 2M connection technology.
The special benefits
Economical as only one sealing technology
is used for all injectors.
No contact with the inlet liner because of
accurate centering.
GRAPHPACK 2M dual column injector adapter
This dual column injector adapter permits the simultaneous
connection of two fused silica capillary columns
to one injector and thus the parallel production
of two chromatograms. Appropriate versions are available
for the GERSTEL injection systems and the injectors
of other GC manufacturers.
If different capillary columns and/or detector systems
are used, you obtain additional information on the
identity and polarity of the chromatographed substances
with only one analysis.
The special benefits
Reduction in analysis time.
Higher-quality information.
Simultaneous operation of capillary columns with
different polarities.
No split distortions due to contact of the capillary
column with the inside wall of the inlet liner thanks
to its special design.
GRAPHPACK 2M MSD adapter
For the low-priced conversion of MSD connections
of various GC manufacturers to GRAPHPACK 2M connection
technology.
The special benefits
Connections compatible with the GERSTEL injection
systems CIS and SIS.
Economical as only one sealing technology is used
for the capillary column.
Leak-free at elevated or fluctuating temperatures
and under high vacuums.
GRAPHPACK 2M dual column interface for MSD
For the simultaneous connection of two capillary
columns to an MSD
The special benefits
Recording of one precolumn and one main column
chromatogram with only one MSD.
Alternative use of two different capillary columns.
GRAPHPACK 3D/2 connection technology
For the rapid, reliable and low-dead-volume connection of two capillary columns
with the same or different diameters, or of different materials.
The components of the GRAPHPACK 3D/2 connection technology are the GRAPHPACK
3D/2 ferrule, the GRAPHPACK 3D/2 connector and the GRAPHPACK 3D/2 screw.
GRAPHPACK 3D/2 column connector
For the connection of two capillary columns with the same or different diameters
or of different materials.
GRAPHPACK 3D/2 column connector with gas connection
For the connection of two capillary columns with the same or different diameters
or of different materials and the connection of make-up gas.
GRAPHPACK 3D/2 crosspieces
For the connection up to 4 capillary columns with the same or different
diameters or of different materials.
GRAPHPACK 3D/2 flow splitter
For installation in a GC. A flow splitter includes two splitter capillaries,
two GRAPHPACK 2M detector adapters and the appropriate GRAPHPACK 2M ferrules.
Apart from the equipment-specific version, there is a universal splitter
available which does not contain the detector adapters or the ferrules.
The special benefits Rapid installation and dismantling.
No loss of selectivity.
Simultaneous use of a wide range of detectors.
|